12/05/2019
4:33 PM
 
Permit No. SFR1904-0045 Permit Type   SINGLE FAMILY R Site Address   821 KENNEY FORT XING
ROUND ROCK, TX 78665
Applied   04/15/2019 Applicant   Meritage Homes
Approved   04/22/2019 Owner   Meritage Homes
Issued   04/22/2019 Contractor   Meritage Homes
Parent Permit No.   Description   New Single Family - 3,832 sq ft
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 05/17/2019PR LAYOUTPAUL MORANPASSEDeTRAKiT Inspection Request5/16/2019 3:02:32 PM 5/16/2019 3:02 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 05/17/2019TEMPORARY METER LOOPPAUL MORANFAILEDeTRAKiT Inspection Request5/16/2019 3:02:32 PM 5/16/2019 3:02 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 5/17/2019 1:24:13 PM 1. Per OnCor: No ground in meter can. 2. Re-stake.

 05/20/2019TEMPORARY METER LOOPJAMES SHINEPASSEDeTRAKiT Inspection Request5/17/2019 1:20:41 PM 5/17/2019 1:20 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 05/22/2019TEMPORARY METER LOOPPAUL MORANFAILEDeTRAKiT Inspection Request5/21/2019 1:22:43 PM 5/21/2019 1:22 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 5/22/2019 3:10:37 PM Missing t-pole

 05/23/2019TEMPORARY METER LOOPPAUL MORANPASSEDeTRAKiT Inspection Request5/22/2019 3:54:01 PM 5/22/2019 3:53 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 05/24/2019SLABPAUL MORANPASSEDeTRAKiT Inspection Request5/23/2019 3:20:56 PM 5/23/2019 3:20 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 05/24/2019BUILDING SEWER LINEPAUL MORANPASSEDeTRAKiT Inspection Request5/24/2019 8:27:02 AM 5/24/2019 8:26 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 5/24/2019 2:57:53 PM T/R 5/24/2019

 05/24/2019BUILDING WATER LINEPAUL MORANPASSEDeTRAKiT Inspection Request5/24/2019 8:27:02 AM 5/24/2019 8:26 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 06/17/2019DRIVEWAYS AND SIDEWALKSPAUL MORANCANCELLEDeTRAKiT Inspection Request6/14/2019 10:23:09 AM 6/14/2019 10:23 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 6/17/2019 10:01:32 AM Duplicate

 06/17/2019DRIVEWAYS AND SIDEWALKSPAUL MORANPASSEDeTRAKiT Inspection Request6/14/2019 11:03:27 AM 6/14/2019 11:03 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 06/18/2019LATHPAUL MORANFAILEDeTRAKiT Inspection Request6/17/2019 3:26:28 PM 6/17/2019 3:26 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 6/18/2019 3:58:31 PM No Lath. No Scaffold.

 06/28/2019TOPOUTPAUL MORANFAILEDeTRAKiT Inspection Request6/26/2019 11:25:44 AM 6/26/2019 11:25 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 7/3/2019 4:05:56 PM 1. Remove scrap/trash piles. Check all sides. 2. Seal brick-pocket/sofits. Check all sides. 3. Remove temp 2x4 supports & blocks. Check all sides. 4. Gas sys not holding test. 5. Repair Tyvek at left back. 6. Seal fresh air duct, right side. Check all sides for penetrations. 7. Missing sewer CO cover, front right. 8. Isolate gas/elect. above kit. island. Check all. 9. Missed wall/roof blocking, right side family room. 10. Missed wall/attic draft-stop, 2nd floor right front bed./entry. 11. Missed WB's (2) 2nd floor. See circled on print. 12. Missed ceiling hip-rafter press block to girder truss, 2nd floor right back bedroom. 13. Support flat 2x4 connecting roof deck above 2nd floor left back bedroom. 14. Missing print/truss calcs. No Insul. No Brick.

 07/03/2019TOPOUTPAUL MORANFAILEDeTRAKiT Inspection Request7/1/2019 8:57:08 AM 7/1/2019 8:57 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 7/3/2019 4:04:44 PM Complete from previous: 1. Remove scrap/trash piles. Check all sides. 2. Seal brick-pocket/sofits. Check all sides. 3. Remove temp 2x4 supports & blocks. Check all sides. 3. Missed header protect from masonry contact, right side entry porch. 4. Gas sys not holding test. 5. Repair Tyvek at left back. 6. Seal fresh air duct, right side. Check all sides for penetrations. 7. Missing sewer CO cover, front right. 8. Isolate gas/elect. above kit. island. Check all. 9. Missed wall/roof blocking, right side family room. 10. Missed wall/attic draft-stop, 2nd floor right front bed./entry. 11. Missed WB's (2) 2nd floor. See circled on print. 12. Missed ceiling hip-rafter press block to girder truss, 2nd floor right back bedroom. 13. Support flat 2x4 connecting roof deck above 2nd floor left back bedroom. No Insul. No Brick.

 07/08/2019TOPOUTPAUL MORANCANCELLEDeTRAKiT Inspection Request7/3/2019 5:27:58 PM 7/3/2019 5:27 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 7/8/2019 10:52:26 AM Per Phil (text)

 07/09/2019TOPOUTPAUL MORANFAILEDeTRAKiT Inspection Request7/8/2019 10:39:43 AM 7/8/2019 10:39 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 7/9/2019 3:36:57 PM 1. Remove scrap/trash piles. Check all sides. 2. Seal brick-pocket/sofits. Check all sides. 3. Missed header protect from masonry contact, right side entry porch. 4. Gas sys not holding test. 5. Repair Tyvek at right, back. 11. Missed WB's (2) 2nd floor. See circled on print. (Missing print for re-inspection) 12. Missed ceiling hip-rafter press block to girder truss, 2nd floor right back bedroom. * No Brick * Ok Insul.

TOPOUTTIM MINIEReTRAKiT Inspection Request7/9/2019 3:51:40 PM 7/9/2019 3:51 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 07/11/2019TOPOUTPAUL MORANFAILEDeTRAKiT Inspection Request7/9/2019 3:53:08 PM 7/9/2019 3:53 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 7/11/2019 3:25:33 PM Complete from previous: 5. Repair Tyvek at right. (Towards the back). 12. Missed ceiling hip-rafter press-block to Girder Truss. (2nd floor right back bedroom) * No Brick * Ok Insul.

 07/12/2019TOPOUTPAUL MORANPASSEDeTRAKiT Inspection Request7/11/2019 3:55:51 PM 7/11/2019 3:55 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 07/17/2019INSULATIONPAUL MORANPASSEDeTRAKiT Inspection Request7/16/2019 11:51:23 AM 7/16/2019 11:51 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 07/17/2019LATHPAUL MORANPASSEDeTRAKiT Inspection Request7/16/2019 11:58:50 AM 7/16/2019 11:58 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

LATHTIM MINIEReTRAKiT Inspection Request7/24/2019 3:59:46 PM 7/24/2019 3:59 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 08/30/2019GAS TESTPAUL MORANFAILEDeTRAKiT Inspection Request8/28/2019 7:06:08 PM 8/28/2019 7:06 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 8/30/2019 3:07:22 PM 1. Locked. 2. Low test. (Minimum 20 psig. 30 psi gauge)

GAS TESTTIM MINIEReTRAKiT Inspection Request9/9/2019 10:04:14 AM 9/9/2019 10:03 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com

 09/12/2019ELEC SERVICEPAUL MORANFAILEDeTRAKiT Inspection Request9/9/2019 10:04:14 AM 9/9/2019 10:03 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 9/12/2019 2:57:17 PM 1. Missing second kitchen sm appliance circuit. 2. Remove unused light box at 2nd floor bedroom. (Light is moved to sloped ceiling.) 3. (Above #2 location) Visible wires & wire-nuts at the edge of light need to be in the new light box.

 09/16/2019GAS TESTPAUL MORANFAILEDeTRAKiT Inspection Request9/11/2019 2:53:26 PM 9/11/2019 2:53 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 9/16/2019 3:14:57 PM Low test. (0 psig) Not complete inspected.

 09/17/2019GAS TESTPAUL MORANFAILEDeTRAKiT Inspection Request9/16/2019 3:32:28 PM 9/16/2019 3:32 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 9/17/2019 2:11:00 PM *** Gauge at meter location reads 0 psig. Not complete inspection

 09/17/2019ELEC SERVICEPAUL MORANPASSEDeTRAKiT Inspection Request9/16/2019 8:16:32 AM 9/16/2019 8:16 AM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 9/17/2019 2:10:59 PM #1 from previous inspection: * Missing second 'kitchen small appliance' circuit. See subpnl in garage.

 09/18/2019GAS TESTPAUL MORANFAILEDeTRAKiT Inspection Request9/17/2019 3:00:07 PM 9/17/2019 2:59 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 9/18/2019 2:23:13 PM 1. Missing long fire-place gas-key.

 09/19/2019GAS TESTPAUL MORANPASSEDeTRAKiT Inspection Request9/18/2019 3:18:44 PM 9/18/2019 3:18 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 9/19/2019 2:10:10 PM Key is returned to kit cab drawer.

 09/30/2019FINALSPAUL MORANFAILED1st (Pd) No Sprinkler permit9/25/2019 5:28:56 PM 9/25/2019 5:28 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com 9/30/2019 2:05:08 PM 1. Missing 6" valve-sleeve cover (817), front left. 2. Missing orange construction fence at front right. 3. Remove blown-trash & scrap. All sides. 4. Cut 3/4" & 1" drain lines 6" above grade, left side (Back of fence). 5. Foyer hall light is in-op. *** Collected Certs. NOTE: Broken vanity cab door, Jack & Jill bath on 2nd floor.

 10/03/2019FINALSPAUL MORANPASSED2nd9/30/2019 3:56:49 PM 9/30/2019 3:56 PM Meritage Homes Contact Name: Meritage Homes Site Address: 821 KENNEY FORT XING Phone: 5126104800 e-Mail: kim.kidd@meritagehomes.com